Products

LXSY-20F半液封水表机芯(摄像专用款)

详细介绍

 

1. Product Introduction

Use: record the total amount of cold water flowing through natural water pipes

 

2. Main features

The movement of the counting mechanism of the word wheel count part of the special liquid package, the whole surface of the long-term and antifreeze. The upper part of the wheel is equipped with a sealing ring to prevent the water inside the seal and the external counter to exchange water, to keep the character display part of the clear. The use of the movement of the general mechanical water meter can be upgraded to two kinds of remote function with a water meter. The first class is a mechanical water meter with additional intelligent camera recognition components, which can realize the function of reading the data of the meter. The picture can be displayed on the computer terminal, and it is easy to deal with the dispute. The second category is attached to the pulse sensor mechanical water meter, pulse signal can be processed to achieve the remote data reading table data, and easy to install. The above two types of mechanical water meters of the technical indicators are in line with national GB / T 778.1 ~ 3-2007 level measurement standards (equivalent to the international standard ISO 4064-1 ~ 3: 2005.IDT level) requirements.

 

3. Service conditions

a)Temperature rating:T30

 

b)Pressure rating:MAP10

 

c)Pressure loss rating:△P63

 

d)Upstream flow field sensitivity rating:U10

 

e)Downstream flow field sensitivity rating:D5

 

f)Ambient humidity:≤93%RH

 

g)Climate and mechanical environment rating:Class B

 

h)Electromagnetic environment rating:E1

 

i)Non-measurable negative test

 

4. Indication error

a)Low area(Q1≤Q≤Q2)The maximum allowable error is ±5%

 

b)High area(Q2≤Q≤Q4)The maximum allowable error is ±2%

 

5. Main technical parameters

Nominal diameter

DN (mm)

Overload flow

Q4 (m3/h)

Common flow

Q3 (m3/h)

Boundary flow

Q2 (m3/h)

Minimum flow rate

Q1 (m3/h)

 Range ratio

R(Q3/Q1)

Accuracy

Level

Minimum reading

(m3)

Maximum reading

(m3)

DN153.1252.50.050.0312580

Level 2

0.000199999.9999
0.0400.025100
0.0320.020125
0.0250.01562160
DN20540.080.0580
0.0640.040100
0.05120.032125
0.0400.025160
DN257.8756.30.1260.0787580
0.10080.063100
0.080640.0504125
0.0630.039375160
DN4020160.3200.20080   
0.001
99999.9999
0.2560.160100
0.20480.128125
DN5031.25250.5000.312580
0.4000.250100
0.3200.200125

 

6.Overall size and weight

Nominal diameterInstallation Diameter (D)Installation height (L1)Movement total height (L2)
mm
DN15Φ69-0 -0.2046+0.10 +076.7
DN20Φ69-0 -0.2046+0.10 +076.7
DN25Φ73.5-0 -0.2046.5+0.10 +081
DN40Φ90-0 -0.2065.5+0.10 +0111
DN50Φ90-0 -0.2065.5+0.10 +0111

Note:size and weight are for reference only.