Products

LXS-20F半液封水表机芯

详细介绍

 

1. Product Introduction

Use: record the total amount of cold water flowing through natural water pipes.

 

2. Main features:

The movement of the counting mechanism of the word wheel count part of the special liquid package, the whole surface of the long-term and antifreeze. It can be used in the domestic water supply pipe network. The technical indicators are in line with national GB / T 778.1 ~ 3-2007 level of measurement standards (equivalent to the international standard ISO 4064-1 ~ 3: 2005.IDT level) requirements.

 

3. Service conditions

a)Temperature rating:T30(The cold water)T90(The hot water)

 

b)Pressure rating:Map10

 

c)Pressure loss rating:△P63

 

d)Upstream flow field sensitivity rating:U10

 

e)Downstream flow field sensitivity rating:D5

 

f)Non-measurable negative test

 

4. Indication error

a)Low area(Q1≤Q≤Q2)The maximum allowable error is ±5%

 

b)High area(Q2≤Q≤Q4)The maximum allowable error is ±2%

 

5. Main technical parameters

Nominal diameter

DN (mm)

Overload flow

Q4 (m3/h)

Common flow

Q3 (m3/h)

Boundary flow

Q2 (m3/h)

Minimum flow rate

Q1 (m3/h)

Range ratio

R(Q3/Q1)

Accuracy

Level

Minimum reading

(m3)

Maximum reading

(m3)

DN153.1252.50.050.0312580level 20.000199999.9999
0.0400.025100
0.0320.020125
0.0250.01562160
DN20540.080.0580
0.0640.040100
0.05120.032125
0.0400.025160
DN257.8756.30.1260.0787580
0.10080.063100
0.080640.0504125
0.0630.039375160
DN4020160.3200.200800.00199999.9999
0.2560.160100
0.20480.128125
DN5031.25250.5000.312580
0.4000.250100
0.3200.200125

 

6.Overall size and weight

Nominal diameterInstallation Diameter (D)Installation height (L1)Movement total height (L2)
mm
DN15Φ69-0 -0.2046+0.10 +076.7
DN20Φ69-0 -0.2046+0.10 +076.7
DN25Φ73.5-0 -0.2046.5+0.10 +081
DN40Φ90-0 -0.2065.5+0.10 +0111
DN50Φ90-0 -0.2065.5+0.10 +0111

 

Note:size and weight are for reference only.